Strikalite Batteries -  -

ALL PRICES INCLUDE VAT

Friday 13 December 2024
Home Login / Register Help / Security Contact Us View Cart  
16mm/G-Scale New/SH
16mm/G-scale Regner live steam locomotives
16mm/Gauge1/Gauge3/G scale Model Train Battery Packs
Accessories
Alkaline Batteries
Battery Chargers
Battery Eliminators & PSUs
Battery Holders
Cordless drill batteries
Diving torch battery packs
NiMH Low Self Discharge Rechargeable Batteries
NiMH Rechargeable Batteries
NiMH Tagged Rechargeable Batteries
Postage
Radio Amateur Battery Packs
Radio Controlled Battery Packs
Sealed Lead Acid batteries
Specialist Battery Packs
Emergency Lighting Modules
Emergency Lighting lights
Central Systems
»»search««
Add to favourites
Online Payments by Trust Payments

 

MINI-SINE
A mini static inverter emergency lighting unit for loads up to 150 watts
 
Mini-Sine is a mini static inverter unit idea for smaller installations and provides emergency back-up for loads up to 150 watts.
Mini-Sine provides emergency back-up for lighting applications where previously it would have been unavailable, for example GU10 and GZ10 mains Voltage lighting installations.Mini-Sine is available in one hour or three hour duration housed within a robust steel enclosure.
Ordering Codes
 
Cat No Description Batteries
MS150/1 150W 1 Hour Static Inverter Emergency Lighting Unit 2x12V 12Ah
MS150/3 150W 3 Hour Static Inverter Emergency Lighting Unit 2x12V 25Ah
 
 
 
 
 
AC SYSTEMS - With Intelligent Datlog™ technology
Our range of static inverter systems are designed to provide emergency lighting (1 to 3 hours as required) at 230VAC (or selected voltage) at 50Hz and includes the latest version of the acclaimed Datlog™ system monitoring and data logging software. The range is designed as the safe option (AC output under emergency conditions).
 
Datlog™ will automatically monitor the load and the battery at a specified time and date if required. Yearly monthly or weekly testing if required ensures that all luminaires and the battery are correctly functioning. The test results and alarms are stored in an internal non-volatile memory. With the optional external printer, the events log can be printed out for permanent record keeping.
.
Datlog™also monitors the battery for continuity and provides temperature compensation and deep discharge protection to ensure maximum life from the batteries. The user-interface is easy to use with scroll buttons to read all operational parameters (available in different languages). Additionally standard alarm outputs allow integration into most building management systems.
 
Where price is an issue systems can be supplied without the Datlog™ facility.
 
Our range of high power static inverter central AC systems are active, off-line-sine-wave inverters and provide the ultimate solution in emergency lighting for medium to large premises. Producing a sinusodial waveform with <5% harmonic distortion into a linear load, the HPAC range is ideal for use with the latest high frequency ballasts and offers a no-break option, for high-pressure discharge lighting schemes,.
HPAC systems are active and offline and use a static switch to supply a by-passed supply during normal conditions with a contactor for the non-maintained output. When there is a power failure the contactor connects the non-maintained load to the inverter that continues to supply the lead.
 
As standard the HPAC range covers single and three-phase outputs, from 1.6kVA to 200kVA. Single or three phase inputs with a single phrase output are available up to 25kVA and three phase inputs with three phase outputs are available from 10kVA to 200kVA.
It should be noted that in order to comply with EN60598.2-22, it is essential that luminaires must not use glow starters or 2 pin lamps with integral starters, therefore electronic ballasts or electronic starters are required.
Ordering Codes
Low Power Systems  
Cat No Max VA Max Watts
LPAC/10/# 150 120
LPAC/20/# 300 240
LPAC/30/# 450 360
LPAC/40/# 600 480
LPAC/50/# 750 600
LPAC/60/# 950 750
LPAC/80/# 1250 1000
LPAC/100/# 1500 1200
Replace # with required duration /1 for 1 hour or /3 for 3 hours
       
High Power Systems
Cat No
Input Phases
Watts VA
Battery Volts
HPAC3/1/#
Single
2400
192
HPAC4/1/#
Single
3200
192
HPAC6/1/#
Single
4800
264
HPAC8/1/#
Single
6400
264
HPAC10/1/#
Single
8000
264
HPAC12/1/#
Single
9600
264
HPAC15/3/#
Three
12000
480
HPAC20/3/#
Three
16000
480
HPAC25/3/#
Three
20000
480
HPAC30/3/#
Three
24000
480
HPAC40/3/#
Three
32000
480
HPAC60/3/#
Three
48000
480
Replace # with required duration /1 for 1 hour or /3 for 3 hours




 

Please phone 01543 683122 for prices

Strikalite - 3 Laurel Drive, Rugeley Road, Burntwood, Staffordshire, WS7 9BL, England
Telephone +44 (0) 1543 683122

Links

©2024 On2net UK e-commerce solutions