CENTRAL BATTERY AND INVERTER SYSTEMS
   
We supply a wide range of AC/DC and AC/DC central systems designed to meet the requirements of a specific applications. Central systems have advantages over self-contained emergency luminaires as follows:
Mains luminaires can be used in place of conventional emergency luminaires allowing higher light levels to be obtained.
The central system and battery cubicles, being centrally located, make maintenance, control and monitoring easier
With a wide range of battery types and sizes the design life of the battery and duration of discharge can be specifically around the parameters of the individual application
The luminaires being mounted remotely from their power source can be placed in environments where a battery may not be capable of correct operation due to extreme heat or cold
 
LOW POWER DC SYSTEMS - LPDC Range
We offer two ranges of lower power systems, using sealed recombination lead acid batteries. The LPDC5 uses the 5 year design life battery, and the LPDC10 the 10 year design life battery. All central systems available with 10 year design life battery's to order.
 
Tables below show the standard ranges but these can be augmented with alternative batteries and durations if required
.
Cabinet sizes (millimetres)
  W1 - Height 455 x Width 405 x Depth 210; W2 - Height 555 x Width 750 x Depth 250
 
LPDC5 Range
 
Power Rating
Power Rating
Nominal Output
Cabinet Type
 
Model*
(W) for 1 hour
(W) for 3 hours
Voltage
 
LPDC5/12/15
140
55
12
W1
 
LPDC5/24/6
84
38
24
W1
 
LPDC5/24/15
216
90
24
W1
 
LPDC5/24/24
300
150
24
W2
 
LPDC5/24/38
480
234
24
W2
 
LPDC5/24/48
550
300
24
W2
 
LPDC5/24/65
960
432
24
W2
 
 
*Specify NM,M operation and duration required (i.e. NM3)
e.g. LPDC 5/12/15/NM1 = 12V 140 Watts Non maintained operation for 1 hour
10 year life cells are also available
 
  HIGH POWER DC SYSTEMS - HPDC Range
 
Our high power systems are manufactured to the highest standards from the UK's leading systems supplier. They offer long trouble free operation with a wide choice of batteries and options for specific applications.
 
HPDC - Valve regulated Lead Acid (VR) range
 
System
Model
Power Rating
Power Rating
Power Rating
Battery
Cabinet
Normal Range
Description
(W) 1 Hour
(W) 2 Hours
(W) 3 Hours
Capacity Ah
Type
24 Volts
HPDC/24/22/*VR
340
195
35
22
F1
12 Cells
HPDC/24/30/*VR
480
280
190
30
F1
HPDC/24/46/*/VR
750
430
300
46
F1
HPDC/24/68/*VR
1050
610
420
68
F1
HPDC/24/84/*VR
1350
790
545
84
F1
HPDC/24/98/*VR
1550
925
635
98
F1
HPDC/24/120/*VR
1925
1120
780
120
F1
50 Volts
HPDC/50/22/*VR
680
390
270
22
F1
24 Cells
HPDC/50/30/*VR
960
560
380
30
F1
HPDC/50/46/*VR
1500
860
600
46
F1
HPDC/50/68/*VR
2100
1220
840
68
F1
HPDC/50/84/*VR
2700
1580
1090
84
F2
HPDC/50/98/*VR
3150
1850
1270
98
F2
HPDC/50/120/*VR
3850
2250
1560
120
F2
HPDC/50/152/*VR
4700
2800
1960
152
F3
110 Volts
HPDC/110/22/*VR
1500
890
610
22
F2
54 Volts
HPDC/110/30/*VR
2150
1250
870
30
F2
HPDC/110/46/*VR
3350
1950
1350
46
F2
HPDC/110/68/*VR
4800
2750
1900
68
F3
HPDC/110/84/*VR
6100
3550
2450
84
F3
HPDC/110/98/*VR
7150
4150
2850
98
(2)F4
HPDC/110/120/*VR
8700
5050
3500
120
(2)F4
Features:
NM, M single or dual output versions for optimum system flexibility
Lift off cubicle covers provide easy access for maintenance
Separate battery and gear compartments for safer operation
Cubicles are manufactured from sheet steel and are epoxy powder coated for a long life in RAL-7032
Choice of Contractors to BS5424 as standard, BS764 types available
A wide battery choice to give optimum flexibility
A range of pre-engineered options to allow complete control and monitoring
 
* Specify NM, M operation and duration required (i.e. NM3) e.g. HPDC/24/30/NM1/VR = 24V 480 watts Non maintained operation for 1 hour
 
To select a model in the HPDC range, insert either NM or M describing the system operation and the system duration 1,2 or hours. Options required should be specified using the relevant suffix. e.g. "/LE" = Low Electrolyte alarm, e.g. HPDC/110/46/M3VR/LE is a 110V maintained system supplying 1350 watts for 3 hours via its Valve Regulated, lead acid battery and has a Low Electrolyte alarm facility.




 

Please phone 01543 683122 for prices

Strikalite - 3 Laurel Drive, Rugeley Road, Burntwood, Staffordshire, WS7 9BL, England